Ice Machine Does Not Fall Off

    Cause of fault: The fault of the water temperature probe is detected, which makes the intelligent control system unable to effectively sense the water temperature and work, misjudging the program error, or controller failure.

    Maintenance method: Use a multimeter to measure the resistance of the water temperature probe (When the water temperature in the tank approaches 0°C, unplug the three conductors in the control box and test the resistance of the two wires on both sides). If the resistance is 27K Above, then judge

    If the controller is bad, it should be replaced. If the resistance is lower than 27K, you must disconnect any of the two wires and adjust the resistance to 27K to 28K through the series resistance.

imm117.jpg

    Ice machine is not water:

    Because of the bad water pump, it is impossible to press water onto the ice tray. If there is a condition, wash the pump every 2 months, if the water filtration system is not good, clean it once a month, or more.

    Change the water filtration system. Otherwise scale can jam the pump or even burn it. The entire ice making water circulation system should be cleaned regularly so as not to affect the ice making effect.